{"database": "openregs", "table": "cfr_sections", "rows": [["49:49:4.1.1.1.32.5.131.22", 49, "Transportation", "II", "", "238", "PART 238\u2014PASSENGER EQUIPMENT SAFETY STANDARDS", "E", "Subpart E\u2014Specific Requirements for Tier II Passenger Equipment", "238.441", "\u00a7 238.441 Emergency roof access.", "FRA", "49 U.S.C. 20103, 20107, 20133, 20141, 20302-20303, 20306, 20701-20702, 21301-21302, 21304; 28 U.S.C. 2461 note; and 49 CFR 1.89.", "64 FR 25660, May 12, 1999, unless otherwise noted.", "[73 FR 6412, Feb. 1, 2008, as amended at 78 FR 71815, Nov. 29, 2013]", "(a)  Existing passenger cars and power cars.  Each passenger car and power car ordered prior to April 1, 2009 and placed in service for the first time prior to April 1, 2011, shall have a minimum of one roof hatch emergency access location with a minimum opening of 26 inches by 24 inches, or at least one structural weak point in the roof providing a minimum opening of the same dimensions, to provide access for properly equipped emergency response personnel. Each emergency roof access location shall be conspicuously marked, and legible and understandable operating instructions shall be posted at or near each such location. On or after January 28, 2015, such markings shall also conform with the requirements specified in \u00a7 238.125.\n\n(b)  New passenger cars.  Each passenger car ordered on or after April 1, 2009 or placed in service for the first time on or after April 1, 2011, shall comply with the emergency roof access requirements specified in \u00a7 238.123.\n\n(c)  New power cars.  Each power car ordered on or after April 1, 2009, or placed in service for the first time on or after April 1, 2011, shall have a minimum of one emergency roof access location, with a minimum opening of 26 inches longitudinally by 24 inches laterally, and comply with the emergency roof access requirements specified in \u00a7\u00a7 238.123(b), (d), and (e)."]], "columns": ["section_id", "title_number", "title_name", "chapter", "subchapter", "part_number", "part_name", "subpart", "subpart_name", "section_number", "section_heading", "agency", "authority", "source_citation", "amendment_citations", "full_text"], "primary_keys": ["section_id"], "primary_key_values": ["49:49:4.1.1.1.32.5.131.22"], "units": {}, "query_ms": 0.3840920398943126, "source": "Federal Register API & Regulations.gov API", "source_url": "https://www.federalregister.gov/developers/api/v1", "license": "Public Domain (U.S. Government data)", "license_url": "https://www.regulations.gov/faq"}